West Virginia Bids > Bid Detail

H146--WATER TOWER ANCHOR INSPECTION

Agency: VETERANS AFFAIRS, DEPARTMENT OF
Level of Government: Federal
Category:
  • H - Quality Control, Testing, and Inspection Services
Opps ID: NBD00159198412560331
Posted Date: Feb 7, 2023
Due Date: Feb 14, 2023
Solicitation No: 36C24523Q0320
Source: https://sam.gov/opp/4475fcd2a3...
Follow
H146--WATER TOWER ANCHOR INSPECTION
Active
Contract Opportunity
Notice ID
36C24523Q0320
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
Looking for contract opportunity help?

Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • All Dates/Times are: (UTC-05:00) EASTERN STANDARD TIME, NEW YORK, USA
  • Original Published Date: Feb 07, 2023 02:02 pm EST
  • Original Response Date: Feb 14, 2023 03:00 pm EST
  • Inactive Policy: Manual
  • Original Inactive Date: Feb 21, 2023
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: H146 - QUALITY CONTROL- WATER PURIFICATION AND SEWAGE TREATMENT EQUIPMENT
  • NAICS Code:
    • 541350 - Building Inspection Services
  • Place of Performance:
    Martinsburg VA Medical Center 510 Butler Ave Martinsburg , WV 25405
    USA
Description
STATEMENT OF WORK
FACILITY SAFETY ANCHOR RECERTIFICATION/ LOAD TEST
VAMC MARTINSBURG
Federal OSHA requires that all roof anchors to be used with Rope Descent Systems (RDS) be re-certified every 10 Years.
Contractor will test and give stamped and sealed Letter of load testing results by a Professional Engineer with the State of West Virginia PE stamp.
All testing will be in accordance with OSHA 29 CFR 1910.140, 1910.66, and 1910.26.
Contractor to provide all parts, tools, equipment, and transportation necessary to complete the requirements for certification of 16 anchor points located in/on the water tower at the Martinsburg VAMC.
Review all existing drawing available for system compliance
Load testing of all available equipment as prescribed by the Engineer of Record
Inspection of all available equipment
Make recommendation for any remedial work that may be required.
Contractor will co-ordinate scheduling and other requirements with the FMS Shop Forman
Contractor is responsible for meeting all local, state, and federal regulation and laws as they pertain to completing this requirement
Attachments/Links
Contact Information
Contracting Office Address
  • 8849 International Drive Suite 215
  • LINTHICUM , MD 21090
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Feb 07, 2023 02:02 pm ESTSources Sought (Original)

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >